Posted by SafeWatchService.com (24.197.166.232) on July 10, 2003 at 22:41:46:
In Reply to: Re: ITI Concord Express posted by jas on July 10, 2003 at 03:17:04:
Actually, that's one more good thing about the Concord Express system - you don't have to program any keypads into it - just power cycle the panel and it should learn the serial from the pad. You "should" be working fine after that.
Now, this being an ADT system, it's possible this is different - but I'm pretty sure it's not - I talked to a tech from ITI the other day about ADT's Concord Express systems - they are not change in any way, just pre-programmed for ADT defaults. So, you should have no problems at all.
Good luck!
: you are talking about a codepad not a control panel, you will have to get into programming and enrol the new/second codepad, "Safewatchservice" will have more detail on what to do but being ADT, you will most likely be locked out of programming.
: : I have a concord express ADT monitored system that was installed by ADT. I was able to come by another control panel that I want to hook to the system. It is the same control panel as the orignally installed control panel. I hooked it up to the system in parallel and the second panel displays all of the system status correctly, but won't contol the system (such as arm, disarm). I am only able to control the system through the original control panel even though the second panel will display the systems state correctly. What is needed to be able to control the system from both panels?
: : Thanks