Posted by jimbob (219.88.170.129) on March 28, 2004 at 19:04:29:
In Reply to: Re: DLS-2002 posted by Erik on March 28, 2004 at 17:29:23:
: : :
: : : Hello all,
: : : tell me please if you know, why when I trying to connect with DLS-2002 to PC1565-2P via modem the Modem and AlarmPanel connects, but after ~ 1 minute the software writes "Waiting for panel answer..." and disconnects.
: : : Also, my modem supported Bell 103, but I dont know are they suports 110bps connection, how I can check this?
: : : Thank you.
: : you have set the panel in direct connect mode before you attempt to connect, ie, [*][8]
: [installer code][499][installer code][499] then try connecting via PC Link/direct connect
: Yes, of course.
: But now the DLS Software connecting to alarm panel, detecting the panel type and version, and after few seconds answers that "modem is not responding", and the connection is aborted...
: I try to connect to the alarm panel via Terminal Emulator, it's connecting, writing Panel Id, and modem returns NO CARRIER signal, but alarm panel is stay on-line, and transmitt data... Is this a modem problem?
: Thanks
why are you using a modem to direct connect??? direct connecting does not require a modem, thats the whole point, in the setup options in DLS 2002 you need to set it up so that whatever coms port you are using is set for direct connect and not to use a modem, if you wanted to communicate remotely to a panel at another site then you would use the modem dial up connection.