|
NETWORK CABLE SIMPLIFIED |
||||||||||||
|
INSTALLATION FORMS
|
COLOR-CODE STANDARDS pin-out diagrams of the two types of UTP Ethernet cables Note that the TX (transmitter) pins are connected to corresponding RX (receiver) pins, plus to plus and minus to minus. And that you must use a crossover cable to connect units with identical interfaces. If you use a straight-through cable, one of the two units must, in effect, perform the cross-over function. Two wire color-code standards apply: EIA/TIA 568A and EIA/TIA 568B. RJ-45 jacks as follows:
at the cable end:
Note that pins 4, 5, 7, and 8 and the blue and brown pairs are not used in either standard. Quite contrary to what you may read elsewhere, these pins and wires are not used or required to implement 100BASE-TX duplexing--they are just plain wasted. Again, the wires with colored backgrounds may have white stripes and may be denoted that way in diagrams found elsewhere. For example, the green wire may be labeled Green-White. The background color is always specified first. Now, all you need to remember, to properly configure the cables, are the diagrams for the two cable ends and the following rules:
It makes no functional difference which standard you use for a straight-thru cable. You can start a crossover cable with either standard as long as the other end is the other standard. It makes no functional difference which end is which. Despite what you may have read elsewhere, a 568A patch cable will work in a network with 568B wiring and 568B patch cable will work in a 568A network. The total length of wire segments between a PC and a hub or between two PC's cannot exceed 100 Meters (328 feet) for 100BASE-TX (and 10BASE-T). MAKE the CABLES
MESSAGE
BOARD SYSTEM The message board replace classified and bulletin board files. You are able to post messages, jobs offer or if you need work, buy, sell, contractors requirements or any message to alarm and security community with a link to a picture or other pages.
|
MESSAGE You are able to post messages, jobs offer or if you need work, buy & sell equipment , contractor requirements or any message to alarm and security community Please post these messages only on the password
protected area of message board
|
© Copyright 1997- 2006 MM C&S Inc. OUR POLICIES
Information in this document is
subject to change without notice.
Other products and companies referred to herein are trademarks or registered
trademarks of their respective companies or mark holders.
UPDATE 12-Nov-2006
MESSAGE BOARD - ALARM RELATED *** ALARM TECH
LINKS TO RELATED SITES *** FREE LINK TO ALARMSBC
WEB
HOSTING * **
DATA CENTER *** HOSTING
PLANS
ALARM COMPANIES
alarm installation companies *
private investigators *
patrol services *
central stations *
fire alarm *
locksmith
FALSE ALARMS >>>
false alarms fees *
British Columbia ( CANADA ) *
California (USA) * other
USA cities
FREE
USER MANUALS ***
JOKES ***
DAILY NEWS ***
GLOSSARY
***
CANADA MAP
ALARM EQUIPMENT >>>
dsc *
ademco *
paradox *
fbi *
pir *
siren *
magnetic contacts *
gas-detectors
wireless devices *
central station
equipment * monitors
*
cameras *
recorders *
switcher & quads
POINTS of
INTEREST
>>>
metric imperial us conversion
* frequently asked
question *
statistics *
how the sensor works
* y2k