MESSAGE
BOARD
FREE
USER
MANUALS
English
International
Chinese
ALARM
COMPANIES
Canada
USA
UK
Australia
New Zeeland
ALARM
EQUIPMENT
DSC
ADEMCO
PARADOX
FBI
-Wireless
Devices
-Central
Station
Equipment
-CCTV
-Fire Alarm
-Gas/CO-Detectors
-Dual Detectors
-Glass Break Detector
-PIR (motion detector)
-Environmental
-Voice Dialer
-Magnetic Contacts
-Transformers
-Batteries
-Siren
Promotion
Special Orders
&
ON SALE
Items
POINTS
of
INTEREST
-Metric Imperial
US
Conversion
-Frequently
Asked Question
-Security Licence
-Statistics
-Standards
-How Devices
Works
-Tips to Improve Security
-Y2K
FALSE
ALARMS
-False Alarms Fees
-British Columbia
-California
-Other US Cities
CENTRAL STATION
INSTALLATION
&
SERVICE

AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES
=CENTRAL STATIONS
PROTOCOLS
=SOFTWARE
=INSTALLATION
TIPS
and
NOTES
=FORMS
=PRODUCTS
OVERVIEW
=TECH
SUPPORT PHONE NUMBERS
WEB HOSTING
=DATA
CENTER and
CONNECTIVITY
=VIRTUAL PACKAGES
DETAILS
=VIRTUAL
PACKAGES PRICES
=WEB CONTROL PANEL
=POLICIES
LINKS TO
RELATED SITES
FREE LINK
TO
AlarmsBC
JOKES
DAILY NEWS
CANADA
MAP
BRITISH
COLUMBIA
MAP
GLOSSARY
SEARCHING
WWW
UNIVERSAL CURRENCY CONVERTER


CONTACT US
|
Expansion Options for Power
Series
DIAGRAM
Pictures PCB Boards

Keypad
Option for Power Series
|
LCD5500Z
Programmable Message LCD Keypad

- Backlit
keypad and display… with backlighting boost
- Large
32-character LCD programmable to display…
- system menus and prompts
- trouble indications
- time & date (12/24 hour clock)
- customizable zone labeling
- viewable event buffer
- HVAC compatible
- Capable of
system programming
- Dimensions…
5.75”W x 4.5”H x 1”D (144 x 114 x 25mm)
|
|
|

|
LCD5501Z
Fixed Message LCD Keypad
- Large fixed
message LCD provides a convenient display of…
- system status
- 12/24 hr clock
- zone scrolling
- Multiple
language versions… English, French, Spanish, & ICON
(Picture)
- 5
programmable function keys
- LED
indicators…Ready, Armed, Trouble
4 keypad-activated alarms… Fire, Auxiliary, Panic, and Duress
- Backlit
keypad and display… with backlighting boost
- Audible
feedback of correct key entries, pre-alert, system trouble, and
tone control
- 4 door
chime options… program each zone with 1 of 4 chime options for
audible distinction
- Capable of
system programming
- Dimensions…
5.75”W x 4.5”H x 1”D (144 x 114 x 25mm)
|
|
PC5508Z,
PC5516Z, and PC5532Z LED Keypads

- 3 keypad
options… 8, 16, and 32 zones
- 5
programmable function keys
- LED
indicators…Ready, Armed, Trouble, Memory, Bypass, Fire, and
Program
- 1 zone
input
- 4
keypad-activated alarms… Fire, Auxiliary, Panic, and Duress
- Backlit
keypad and display… with backlighting boost
- Audible
feedback of correct key entries, pre-alert, system trouble, and
tone control
- Capable of
system programming
- Dimensions…
5.75”W x 4.5”H x 1”D (144 x 114 x 25mm)
|
|
|
|
LCD5501Z32
Fixed Message LCD Keypad with Integrated Wireless Receiver

The LCD5501Z32
keypad/receiver combines a Fixed Message LCD keypad, a PC5132
wireless receiver and an on-board zone input into a simple
integrated product, making the addition of wireless accessories,
such as sensors, keys, and keypads, quick and easy. |
SL-8
and PC1555RKZ LED Keypads
( DISCONTINUED )
SL-8
- 8 zone LED
keypads
- LED
indicators…Ready, Armed, System
- 1 zone
input on PC1555RKZ • Backlit keypad and display… with
backlighting boost
- Audible
feedback of correct key entries, pre-alert, system trouble, and
tone control
- Capable of
system programming
- Dimensions…
SL-8 : 2.5”W x 4.6”H x 1”D (65 x 117 x 25mm)
|

- 8 zone LED
keypads
- LED
indicators…Ready, Armed, System
- 1 zone
input on PC1555RKZ • Backlit keypad and display… with
backlighting boost
- Audible
feedback of correct key entries, pre-alert, system trouble, and
tone control
- Capable of
system programming
- Dimensions…
PC1555RKZ : 5.5”W x 4.5”H x 1”D (144 x 114 x 25mm)
NOTE = PC-1555RKZ IS NOT
INTERCHANGEABLE WITH PC-1550RKZ |

Intercom
DISCONTINUED
The power to listen in and communicate anywhere
in and around the premises
 |
Audio Interface Module PC-5936
works with power 832 and 864 c.panels
PC-5928 works only with
power 832 c.panels
This module will provides up to seven intercoms
(including two for exterior entrances) each with full two-way
communications between any station and room monitoring. The internal
intercoms can operate like a speakerphone and answer incoming phone
calls. Intercoms can also broadcast burglar and fire alarm events.
The central monitoring station can activate all intercoms to conduct
two-way conversation or to listen in on any room. |
Interior Intercom Station
Two-way intercom, background music and room
monitoring. Each
station can be used to initiate or receive pages, answer incoming
calls, answer the doorbell, monitor rooms or sound an alarm
follower. An audio interface module installed with the
main controller is required. Each
station must be home-run to the interface module using shielded 22
gauge, 4-conductor wire. |

|
Exterior Intercom Station
DISCONTINUED
Use up to
two exterior audio stations with your alarm system. It is
housed in a gray fade-resistant case, designed for outside use.
Each station has a separate microphone and speaker. Each
station must be home-run to the interface module using shielded 22
gauge, 4-conductor wire. The station can be used to sound the
doorbell chime on interior audio stations. |
 |

8
Zone Expansion Module PC-5108
|
Adds 8 hardwired zones to the alarm system.
|
|
 |
|

Output Current
Modules
PC-5208 and PC5204
PC5208
8 Output
Low-Current Module |
PC-5208 |
|
|
 |
Adds 8 programmable outputs to
the alarm system. Each output is rated at 50mA. Can be
programmed to respond to one of 14 different system conditions .
Ideal for interfacing to home automation controller (Stargate, Time
Commander Plus, or HomeVision) or directly to X10 PowerFlash Module.
|
PC5204ulc
Four Output High
Current Module
Provides 1 Amp of additional
current (at 12VDC) for the alarm system and components. Also
adds 4 high current programmable outputs for door strikes, bells,
and more. Requires it's own 16VAC 40VA transformer , backup battery
, and enclosure |

PC-5204ULC |

Printer
Module PC-5400ULC
|

|
Allows the alarm
system to print reports to a serial printer. Prints 40 or 80
column on printers with baud rates of 300, 1200, 2400, or 4800.
Prints: zone, time, date & event type as they occur. |
|
|

Escort
Voice Assisted Telephone Control:
PC-5580 ESCORT MODULE WITH
BUILT IN INTERFACE FOR X-10
PC5580TC ESCORT MODULE WITH BUILT IN THERMOSTAT
INTERFACE

The Escort telephone access module can turn any touch-tone telephone, any- where
in the world, into a Power832 system keypad with clear voice prompting and full
customer control of their integrated
security system. The system's voice prompt
gives plain language prompts in English, French, or Spanish, directing you
through the system. Remote telephone access is available from your car, your
office, or even your vacation spot.

Wireless
Receiver pc-5132
433 MHz (900MHz is
Discontinued)
Spread Spectrum Wireless Receivers
|

|
This receiver
module, which can be placed anywhere on the system, will receive
signals from up to 32 wireless
sensors. Each sensor is
supervised for low battery and tampering. Features a
orthogonal antenna arrangement for better RF reception.
Detects RF jamming as a zone tamper. The wireless sensors
can be assigned to zones 1 to 32 only.
|
|
|
PC5720
Fire/ Printer / DVACS Module
Canada only
- a zone expansion module which can also be used to provide
either a serial printer or DVACS communications interface
- 8 zone inputs include :
2 Class A supervisory waterflow zones
ground fault detection zone
5 general purpose fire or burglary zones
- as RS232 printer interface :
baud rates… 300, 1200, 2400, 4800
connect printer up to 200' (61m) from the PC5720 module
- as DVACS interface :
provides ULC Level 3 Line Security.
provides full DVACS reporting of all system events.
module is pre-programmed to SIA zone definitions
PC5400DV -
DVACS Interface Module
- both PC5400 and PC5400DV may be used at the same time on a system
- provides ULC Level 3 Line Security.
- provides full DVACS reporting of all system events.
- module is pre-programmed to SIA zone definitions
- events simultaneously communicated via DVACS and other installed
communications mode such as digital or cellular
- full cross supervision between the system control panel and the
DVACS module e.g… problems with one will be communicated to the
central station by the other.
- central station requires Sur-Gard receiver with DVL2A version 2 or
higher software.
- complete with 8 pin jack, and communications and power cables for
connection to F1/F2 subset.
- connect up to 1000' (305m) from control panel via KEYBUS
module current draw : 65mA @ 12VDC
|