MESSAGE
BOARD
FREE
USER
MANUALS
ALARM
COMPANIES
Alarm Installation
P. I.
Patrol Services
Central Stations
Fire Alarm
Locksmith
ALARM
EQUIPMENT
DSC
ADEMCO
PARADOX
FBI
Wireless_Devices
Central
Station
CCTV
Fire Alarm
Gas/CO-Detectors
Dual Detectors
Glass Break Detector
PIR (motion detector)
Environmental
Magnetic Contacts
Transformers
Batteries
Siren
Discontinued
Items
POINTS
of
INTEREST
Metric Imperial
US
Conversion
Frequently
Asked Question
Statistics
How Devices
Works
Y2K
FALSE
ALARMS
False Alarms Fees
British Columbia
California
Other US Cities
FREE LINK
TO
AlarmsBC



AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES
=CENTRAL STATIONS
PROTOCOLS
=SOFTWARE
=INSTALLATION
TIPS
and
NOTES
=FORMS
=PRODUCTS
OVERVIEW
=TECH
SUPPORT PHONE NUMBERS
WEB HOSTING
=DATA
CENTER and
CONNECTIVITY
=VIRTUAL PACKAGES
DETAILS
=VIRTUAL
PACKAGES PRICES
=WEB CONTROL PANEL
=POLICIES
LINKS TO
RELATED SITES
JOKES
DAILY NEWS
CANADA MAP
GLOSSARY
SEARCHING
WWW
UNIVERSAL CURRENCY CONVERTER
CONTACT US
|
BACK TO MAXSYS PAGES
MAIN PANEL
KEYPAD
MODULES
MAIN PANEL
- 2.2A
power supply
- 32 true
partitions…separate or shared from other partitions. User
access from any keypad, dependent on partition assignment
- True
independent partitions
-
Individual bell outputs, access codes, entry exit timers, zone,
etc.
- 16 main
board zones expandable to 256
-
Expandable with 30 PC6108 modules
- DEOL
supervision
- 16
main board zones

- 64 LCD Keypads
on the system
- 2
hardwired LCD keypads
- PC6501 alphanumeric LCD keypad
- PC6501T alphanumeric LCD keypad with tamper
- 210 pgm output
- Up to 66
high current outputs…2 on main panel plus
:
PC6204 - 4 relay power supply module…add up to 16 modules
PC6216 - 16 low current output module…add up to 9 modules
- Up to 32
access-controlled doors using up to 16 PC6820 modules
|
- 2
programmable outputs…each output can be programmed for 1 of 56
PGM output options
- 1
supervised programmable bell/siren output
- 1 12VDC
switched programmable auxiliary power supply
- High and
low battery charging current
- 4-wire
connection to Ebus (communication bus) - for easy connection
of modules
- 3-wire
connection for Backbone communication bus
- for addition of PC644X modules
- 3000
event buffer…2500 events can be viewed through the keypad,
including date and time stamp
- 4 user
types…Basic,
Advanced, Supervisor, Master
- Zone
types include:
- standard delay
- momentary arm
- force arm delay
- maintained arm
- auxiliary delay
- 24hr holdup
- instant
- auxiliary
- interior
- 24hr auxiliary
- 24hr bell
- 24hr medical
- 24hr bell/buzz
- seismic
- 24hr buzzer
- LINKS supervisory
- standard fire
- LINKS answer
- auto verify
- Both
6010 and 6204 have a 2.2A power supply
- PC6010
can provide up to 1.7A
of Aux. output current
- PC6204
can provide up to 1.5A
of Aux. output current\Both PC6010 and PC6204 support up to 1.4A
of battery charging current
-
Communicates using the SIA
or Contact ID formats
-
Links1000/GSM1000 cellular communication
- 32
account codes
- 1000
users
|
| |
|

KEYPAD
LCD 6501 / LCD
6501T
-
Alphanumeric LCD display
- With new
E-Z Prompt user flow, prompts user with simple questions
- Built-in
piezo buzzer
- Full
annunciation of zones and system status
- Up to 16
keypads on system
- Maximum
current draw of 55mA (from Ebus) 90mA with backlighting boost
- Dimensions
: 5.5" x 4.5" x 1" deep (150 x 114 x 25mm)
|
 |
| |
|

MODULES
|
PC6108 -
8 zone expander
The PC6010 is
easily expanded by adding PC6108A modules via 4 wire communications
bus (Ebus).
- 8 zone
expansion module
- Add up to
30 modules for total of
256 zones on the system
- Supports
DEOL zone loops
- Nominal
current draw of 30mA
- AUX Output:
12VDC, 250mA max.
- Supervised
for tamper
- Low Ebus
supervision
|
 |
PC 6204 High
current output modules
- 2.2A power
supply
Supports high and low battery charging current (1.4A or 360mA)
- Up to 16
modules on system (up to 64 high current outputs)
- Output
current: 1A, 12VDC
- Each output
programmable for 1 of 56 options
- Minimum
80VA 16-18 volt transformer required
- Minimum 4Ah
battery required, up to 36Ah max.
- AUX
current: 680mA max. high battery charge 1.7A max.
- Low Ebus
supervision
- 4
programmable relay contacts
- Supervised
for tamper and troubles (low battery, AC trouble, etc.)
- Latching
output option
|
 |
PC 6216 Low current output modules
- 16 outputs
per module – 9 modules per system
- All 16
outputs can be programmed on each module, 1 of 56 options each
- Nominal
current draw of 15mA plus power required by outputs
- Output
current: 50mA, 12VDC
- Low Ebus
supervision
- Supervised
for tamper
- Latching
output option
|
 |
PC 6400 Serial printer interface
module
- Baud rate –
4800
- RS-232
protocol
- Connects to
panel via 4-wire Ebus
- Supervised
for tamper and off line trouble
|
 |
PC 6442 /6443 Interface modules
- High speed
2 way communication port module for customized applications
- 115.5K Baud
access
- 1.5Amp
power supply with battery backup
- AUX
current: 50mA
- Connects to
panel via Backbone
- 720mA
battery charging current
- 1 of each
module per system
|
 |
PC 6820
Access control
- 2
programmable supervised zones
- Zones may
be programmed:
Standard
Force Arm Delay
Auxiliary Delay
- Up to 16
PC6820 modules can be added (up to 32 access points)
- Does not
lose any system programming when module is powered down
- 6 low
current outputs
2 LED terminals (to the LED input of the reader)
2 BUZ terminals (to the buzzer input of the reader)
2 OUT terminals
- Auxiliary
output supply: 12VDC, 125mA max.
- LK1/LK2
door strike power: 12VDC, 250mA max.
- Reader
power: 5VDC, 125mA max.
- Reader
power: 12VDC 125mA max.
- Battery
required – 12VDC 7.0Ah recommended rechargeable lead acid
- Transformer
required – 16.5VAC, 40VA
- Output
Voltage – 13.8VDC (with normal AC and fully charged
battery)
- 720mA
battery charging current
|
|
| |
|
| |
|

|