ALARMSBC LOGO---back to home page

EQUIPMENT DSC

THIS  RESTRICTED  AREA IS FOR ALARM COMPANIES AND SECURITY EMPLOYEES ONLY


MESSAGE
BOARD


FREE USER
MANUALS


ALARM
COMPANIES

Alarm Installation 
P. I.
Patrol Services  
Central Stations
Fire Alarm  
Locksmith


ALARM
EQUIPMENT

DSC
ADEMCO 
PARADOX 
FBI

Wireless_Devices 
Central  Station
CCTV
Fire Alarm
Gas/CO-Detectors
Dual Detectors
Glass Break Detector 
PIR (motion detector)
Environmental
Magnetic Contacts
Transformers
Batteries
Siren  

Discontinued
Items


POINTS
of
INTEREST
 

Metric Imperial US Conversion
Frequently Asked Question
Statistics
How  Devices Works
Y2K


FALSE ALARMS

False Alarms Fees
British Columbia
California
Other US Cities


FREE  LINK
TO
 AlarmsBC

 


Our Guestbook


THIS  RESTRICTED  AREA IS FOR ALARM COMPANIES AND SECURITY EMPLOYEES ONLY

AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES

=CENTRAL  STATIONS  PROTOCOLS 
=SOFTWARE 
=INSTALLATION TIPS and NOTES 
=FORMS 

=PRODUCTS OVERVIEW 
=TECH SUPPORT PHONE NUMBERS 


WEB HOSTING

=DATA CENTER and
CONNECTIVITY

=VIRTUAL PACKAGES DETAILS
=VIRTUAL PACKAGES PRICES
=WEB CONTROL PANEL

=POLICIES


LINKS TO
RELATED SITES


JOKES


DAILY NEWS


CANADA MAP


GLOSSARY


SEARCHING 
WWW 


UNIVERSAL  CURRENCY  CONVERTER


CONTACT US

 


BACK TO MAXSYS PAGES
     

maxsys 6000 
 

MAIN PANEL      KEYPAD      MODULES


    MAIN PANEL

 

  • 2.2A power supply
  • 32 true partitions…separate or shared from other partitions. User access from any keypad, dependent on partition assignment
    • True independent partitions
    • Individual bell outputs, access codes, entry exit timers, zone, etc.
  • 16 main board zones expandable to 256
    • Expandable with 30 PC6108 modules
    • DEOL supervision
    • 16 main board zones

 

 

  • 64 LCD Keypads  on the system
  • 2 hardwired LCD keypads
    - PC6501 alphanumeric LCD keypad
    - PC6501T alphanumeric LCD keypad with tamper
  • 210 pgm output
  • Up to 66 high current outputs…2 on main panel plus :
    PC6204 - 4 relay power supply module…add up to 16 modules
    PC6216 - 16 low current output module…add up to 9 modules
  • Up to 32 access-controlled doors using up to 16 PC6820 modules
  • 2 programmable outputs…each output can be programmed for 1 of 56 PGM output options
  • 1 supervised programmable bell/siren output
  • 1 12VDC switched programmable auxiliary power supply
  • High and low battery charging current
  • 4-wire connection to Ebus (communication bus) - for easy connection of modules
  • 3-wire connection for Backbone communication bus - for addition of PC644X modules
  • 3000 event buffer…2500 events can be viewed through the keypad, including date and time stamp
  • 4 user types…Basic, Advanced, Supervisor, Master
  • Zone types include:
    - standard delay
    - momentary arm
    - force arm delay
    - maintained arm
    - auxiliary delay
    - 24hr holdup
    - instant
    - auxiliary
    - interior
    - 24hr auxiliary
    - 24hr bell
    - 24hr medical
    - 24hr bell/buzz
    - seismic
    - 24hr buzzer
    - LINKS supervisory
    - standard fire
    - LINKS answer
    - auto verify

 

  • Both 6010 and 6204 have a 2.2A power supply
  • PC6010 can provide up to 1.7A
    of Aux. output current
  • PC6204 can provide up to 1.5A
    of Aux. output current\Both PC6010 and PC6204 support up to 1.4A
    of battery charging current
  • Communicates using the SIA
    or Contact ID formats
  • Links1000/GSM1000 cellular communication
  • 32 account codes
  • 1000 users

 

   

TOP OF PAGE


    KEYPAD

  LCD 6501 / LCD 6501T
  • Alphanumeric LCD display
  • With new E-Z Prompt user flow, prompts user with simple questions
  • Built-in piezo buzzer
  • Full annunciation of zones and system status
  • Up to 16 keypads on system
  • Maximum current draw of 55mA (from Ebus) 90mA with backlighting boost
  • Dimensions : 5.5" x 4.5" x 1" deep (150 x 114 x 25mm)

 

lcd 6501

   

TOP OF PAGE

 


    MODULES

 PC6108 - 8 zone expander

The PC6010 is easily expanded by adding PC6108A modules via 4 wire communications bus (Ebus).

  • 8 zone expansion module
  • Add up to 30 modules for total of
    256 zones on the system
  • Supports DEOL zone loops
  • Nominal current draw of 30mA
  • AUX Output: 12VDC, 250mA max.
  • Supervised for tamper
  • Low Ebus supervision

6108 expander

  PC 6204 High current output modules
  • 2.2A power supply Supports high and low battery charging current (1.4A or 360mA)
  • Up to 16 modules on system (up to 64 high current outputs)
  • Output current: 1A, 12VDC
  • Each output programmable for 1 of 56 options
  • Minimum 80VA 16-18 volt transformer required
  • Minimum 4Ah battery required, up to 36Ah max.
  • AUX current: 680mA max. high battery charge 1.7A max.
  • Low Ebus supervision
  • 4 programmable relay contacts
  • Supervised for tamper and troubles (low battery, AC trouble, etc.)
  • Latching output option

   PC 6216 Low current output modules
  • 16 outputs per module – 9 modules per system
  • All 16 outputs can be programmed on each module, 1 of 56 options each
  • Nominal current draw of 15mA plus power required by outputs
  • Output current: 50mA, 12VDC
  • Low Ebus supervision
  • Supervised for tamper
  • Latching output option

   PC 6400  Serial printer interface module
  • Baud rate – 4800
  • RS-232 protocol
  • Connects to panel via 4-wire Ebus
  • Supervised for tamper and off line trouble

   PC 6442 /6443 Interface modules 
  • High speed 2 way communication port module for customized applications
  • 115.5K Baud access
  • 1.5Amp power supply with battery backup
  • AUX current: 50mA
  • Connects to panel via Backbone
  • 720mA battery charging current
  • 1 of each module per system

PC 6820 Access control
  • 2 programmable supervised zones
  • Zones may be programmed:
    Standard
    Force Arm Delay
    Auxiliary Delay
  • Up to 16 PC6820 modules can be added (up to 32 access points)
  • Does not lose any system programming when module is powered down
  • 6 low current outputs
    2 LED terminals (to the LED input of the reader)
    2 BUZ terminals (to the buzzer input of the reader)
    2 OUT terminals
  • Auxiliary output supply: 12VDC, 125mA max.
  • LK1/LK2 door strike power: 12VDC, 250mA max.
  • Reader power: 5VDC, 125mA max.
  • Reader power: 12VDC 125mA max.
  • Battery required – 12VDC 7.0Ah recommended rechargeable lead acid
  • Transformer required – 16.5VAC, 40VA
  • Output Voltage – 13.8VDC (with normal AC and fully charged battery)
  • 720mA battery charging current

 

   
   

TOP OF PAGE


 

 

© Copyright 1997- 2008
Information in this document is subject to change without notice.
Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
UPDATE 26-Jan-2008
MMC&S Inc.

  
 


MESSAGE BOARD   ***   ALARM COMPANIES  ***   FREE  USER MANUALS

ALARM EQUIPMENT >>>  dsc * ademco paradox  *  fbi  *  gas/co - detectors  * wireless devices  * fire alarm
 motion detectors *   dual detectors * glass break detectorsmagnetic contactstransformers * battery * siren
 Environmentalcentral station equipmentmonitors * cameras *  recorders * switcher & quads  

INSTALLATION / SERVICE / MONITORING

POINTS  of  INTEREST >>> metric imperial us conversion * frequently asked question  *  statistics 
 how the sensor works  *  y2k * basic security systems 101 

FALSE ALARMS >>>  false alarms fees British Columbia ( CANADA )  *  California (USA)  *  other USA cities  

LINK to AlarmsBC   ***    LINKS TO RELATED SITES   ***     SEARCHING WWW  

WEB HOSTING   * **   DATA CENTER ***  HOSTING PLANS 

JOKES  ***   DAILY NEWS   ***   GLOSSARY   ***    CANADA MAP

 ALARM TECH  HELP >>>  INSTALLATION TIPS  >>> SENTROL Application notes  * ULC Installation tips 
 ULC Level of protection   *  Default Installer codes  *  ADT alarm panel -  Cross Reference   *  Network Cable Simplified 
etc...  etc....

CENTRAL STATIONS PROTOCOLS   *     TECH SUPPORT PHONE NUMBERS   *   SOFTWARE


CONTACT US