ALARMSBC LOGO---back to home page

Detection Systems  & Radionics

THIS  RESTRICTED  AREA IS FOR ALARM COMPANIES AND SECURITY EMPLOYEES ONLY


MESSAGE
BOARD


FREE USER
MANUALS


ALARM
COMPANIES

Alarm Installation 
P. I.
Patrol Services  
Central Stations
Fire Alarm  
Locksmith


ALARM
EQUIPMENT

DSC
ADEMCO 
PARADOX 
FBI

Wireless_Devices 
Central  Station
CCTV
Fire Alarm
Gas/CO-Detectors
Dual Detectors
Glass Break Detector 
PIR (motion detector)
Environmental
Magnetic Contacts
Transformers
Batteries
Siren  

Discontinued
Items


POINTS
of
INTEREST
 

Metric Imperial US Conversion
Frequently Asked Question
Statistics
How  Devices Works
Y2K


FALSE ALARMS

False Alarms Fees
British Columbia
California
Other US Cities


FREE  LINK
TO
 AlarmsBC

 


Our Guestbook


CONTACT US

 

BACK TO Y2K MAIN PAGE 
BACK TO POINTS OF INTEREST 

 

Detection Systems, Inc. & Radionics, Inc. Year 2000 Product Compliance Matrix*
The following Year 2K compliance letters have been revised 11/11/99. These revisions rescind all other versions previously released.

Items in red are items that have changed since the previous revision. Only products requiring Year 2000 compliance are listed on this matrix. All other products do not operate by date and time function and do not require compliance listing.

Hardware Products

Detection Systems Panels
Model # Description Test Required Test Complete Year 2000 Compliant
DS7060 Control / Communicator - 6 Zone YES Completed YES
DS7080i Control / Communicator - 8 Zone YES Completed YES
DS7080iP32 Control / Communicator - 8 Zone exp. to 32 YES Completed YES
DS7090 Control / Communicator - 6 Zone YES Completed YES
DS7090TM Control / Communicator - 6 Zone YES Completed YES
DS7090i Control / Communicator - 6 Zone YES Completed YES
DS7090TMi Control / Communicator - 6 Zone YES Completed YES
DS7100 Control / Communicator - 15 Zone YES Completed YES
DS7400 Control / Communicator -12 8 Zone Multiplex YES Completed YES
DS7400X Control / Communicator -12 8 Zone Multiplex YES Completed YES
DS7400Xi Control / Communicator -12 8 Zone Multiplex YES Completed YES
DS7400Xi +3 Control / Communicator -12 8 Zone Multiplex YES Completed YES
         
         
Radionics Panels
Model # Description Test Required Test Complete Year 2000 Compliant
D1500 / D2000 Dialer No Touch Tone/Touch Tone YES YES YES
D2012 / D2012-05A /D2012U Control / Communicator - 6 Zone YES Completed YES
D2112 Control / Communicator - 8 Zone YES Completed YES
D2212 Control / Communicator - 8 Zone exp. to 24 YES Completed YES
D2412 /D2412U Control / Communicator 6 Zone exp. to 24 YES Completed YES
D2812 /D2812U Control / Communicator 6 Zone exp. to 24 YES Completed YES
D3000 3 Zone, 6V Control Communicator YES YES YES
D3012 4 Zone, 12 V, Control Communicator YES YES YES
D4000 / D8000 Control / Communicator - 4 Zone / 8 Zone 6V YES YES YES
D4012 / D8012 Control / Communicator - 4 Zone / 8 Zone 12V YES YES YES
D4112 Control / Communicator - 6 Zone YES Completed YES
D6112 Control / Communicator - 8 Zone exp. To 16 YES Completed YES
D7112 Control / Communicator - 8 pt. Exp. To 48 YES Completed YES
D7212B/B1 Control / Communicator - 8 pt. Exp. To 48 YES Completed YES
D7412/D7212 Control / Communicator - 8 pt. Exp. To 75 with/without access YES Completed YES
D8112 Control / Communicator - 8 Zone possibly exp. To 135 zones YES Completed Conditional - See Footnote A, C
D9112B/B1 Control / Communicator - 8 pt. Exp. To 135 YES Completed YES
D9124 Fire Control / Communicator, 24 Volt YES Completed YES
D9412/D9112 Control / Communicator - 8 pt exp. To 246 with/without access YES Completed YES
         
         
Radionics Receivers
Model # Description Test Required Test Complete Year 2000 Compliant
D6000 Central Station Receiver YES Completed Conditional - See Footnote A
D6500 Central Station Receiver YES Completed YES
D6600 Central Station Receiver YES Completed YES
         
         
Readykey Access Control
Model # Description Test Required Test Complete Year 2000 Compliant
K1100 Two Door Access Control YES YES YES V2.0 or higher
K2100 Four Door Access Control YES YES YES V2.0 or higher
K6000-AM, K6000-MS Readykey for Windows Software (PC) YES YES NO
K6100 Readykey for Windows Software (PC) YES YES YES V2.0 or higher
K6100-CNC Readykey "Central Network Controller" Hardware YES YES V1.5 Conditional. See Footnote D. V1.6 Compliant
         
         
Fire Panels
Model # Description Test Required Test Complete Year 2000 Compliant
D2071 / D2071A / D2071AC / DS9471 / DS9471C Fire Communicator, 3 Zone YES YES YES
D4013 / D8013 Fire Control Communicator - 4 zone / 8 zone 12V YES YES YES
D7022 Fire Control, 24V, 2 Zone Conv. YES YES YES
D7024 / DS9400 Fire Control / Comm., 24V, 4 Zone Conv. YES YES YES
D8024 Analog Fire Control, 24V, 1 Loop YES YES YES
D8112 Control / Communicator - 8 Zone possibly exp. To 135 zones YES Completed Conditional - See Footnote A, C
D9024 Analog Fire Control, 24V, 3 Loop YES YES YES
D9124 Addressable Fire Control - 248 pt. YES YES YES
D10024 Analog Fire Control, 24V, 5 Loop YES YES YES
         
Year 2000 Product Compliance - Software Products
 
Security Escort
Model # Description Test Required Test Complete Year 2000 Compliant
SE1000 Escort Central Monitoring Software YES YES YES
SE2005 Escort Software 32 bit - 500 YES YES YES
SE2010 Escort Software 32 bit - 1,000 YES YES YES
SE2050 Escort Software 32 bit - 5,000 YES YES YES
SE2100 Escort Software 32 bit - 10,000 YES YES YES
   
 
WDSRP (Windows, Detection Systems Remote Programming)
Panel Model # Description Test Required Test Complete Year 2000 Compliant
DS7060 Control / Communicator - 6 Zone YES YES YES
DS7080i Control / Communicator - 8 Zone YES YES YES
DS7080iP32 Control / Communicator - 8 Zone exp. to 32 YES YES YES
DS7090 Control / Communicator - 6 Zone YES YES YES
DS7090TM Control / Communicator - 6 Zone YES YES YES
DS7090i Control / Communicator - 6 Zone YES YES YES
DS7090TMi Control / Communicator - 6 Zone YES YES YES
DS7100 Control / Communicator - 15 Zone YES YES YES
DS7400 Control / Communicator -12 8 Zone Multiplex YES YES YES
DS7400X Control / Communicator -12 8 Zone Multiplex YES YES YES
DS7400Xi Control / Communicator -12 8 Zone Multiplex YES YES YES
DS7400Xi +3 Control / Communicator -12 8 Zone Multiplex YES YES YES
         
DSRP ( Detection Systems Remote Programming)
Panel Model # Description Test Required Test Complete Year 2000 Compliant
DS7090 Control / Communicator - 6 Zone YES YES YES
DS7090TM Control / Communicator - 6 Zone YES YES YES
DS7100 Control / Communicator - 15 Zone YES YES YES
         
RAM II (Remote Account Manager)
Panel Model #   Test Requires Test Complete Year 2000 Compliant
D2012 / D2012-05A /D2012U Control / Communicator - 6 Zone YES YES YES
D2112 Control / Communicator - 8 Zone YES YES YES
D2212 Control / Communicator - 8 Zone exp. to 24 YES YES YES
D2412 /D2412U Control / Communicator 6 Zone exp. to 24 YES YES YES
D2812 /D2812U Control / Communicator 6 Zone exp. to 24 YES YES YES
D4112 Control / Communicator - 6 Zone YES YES YES
D6112 Control / Communicator - 8 zone exp. to 16 YES YES YES
D7112 Control / Communicator - 8 pt. Exp. to 48 YES YES YES
D7212B/B1 Control / Communicator - 8 pt. Exp. to 48 YES Completed YES
D8112 Control / Communicator - 8 Zone possibly exp. To 135 zones YES YES YES
D9124 Fire Control / Communicator, 24 Volt YES YES YES
D9112B/B1 Control / Communicator - 8 pt. Exp. To 135 YES YES YES
         
         
RAM III (Remote Account Manager)
Panel Model # Description Test Required Test Complete Year 2000 Compliant
D7212 Control / Communicator - 8 pt. Panels exp. To 75 pts. YES YES YES
D7412 Control / Communicator - 8 pt. Panels exp. To 75 pts. YES YES YES
D9112 Control / Communicator - 246 pt. YES YES YES
D9412 Control / Communicator - 246 pt. with Access YES YES YES
         
         
Safecom
Model # Description Test Required Test Complete Year 2000 Compliant
SC9000 Base Station Receiver Software and related products YES YES YES
ST1000 Central Station Receiver Software YES YES YES
SC9001 UL Listed Central Station Computer YES YES No See Note B
SC4000 Full Data Transfer System No - No Clock N/A YES
SC2104 Two Way Slave Communicator No - No Clock N/A YES
SC3100 Dialer Interface/Radio Module No - No Clock N/A YES
 
 
Keypads
Model # Description Test Required Test Complete Year 2000 Compliant
D202A/W System Keypads. These devices are slave peripherals and contain no time / day / date functions. All displayed information is provided by the Alarm Panels they are connected to. Please locate the appropriate panel model number to verify its compliance. N/A N/A YES
D220A/AW N/A N/A YES
D222/W N/A N/A YES
D223/W N/A N/A YES
D204RF N/A N/A YES
D205 N/A N/A YES
D206, D420 N/A N/A YES
D279 N/A N/A YES
D360, D620, D636A N/A N/A YES
D720 N/A N/A YES
D1252A (ALPHA II)/W, D1252AF N/A N/A YES
D1255 (ALPHA IV)/W N/A N/A YES
D1256, D1257 N/A N/A YES
Rev. 11/9/99





Footnote A - Several products are listed as "conditional" compliance. These products have never had leap year capabilities of any type. They do however function with no other Year 2000 issues.

Footnote B - SAFECOM SC9001 UL Listed Computer System - The Compaq® 386 PC ships as part of the SC9001 UL Listed Central Station system contains a non-compliant Year 2000 BIOS. After the Year 2000 roll over occurs, the PC's time and date MUST be manually reset at least once, even if the date appears to be correct! If power is not applied during the Year 2000 roll over, the system clock resets to January 4, 1980. This can be manually reset to the Year 2000 for continued normal operations.

Note: Dates must be entered in a 4 digit format I.e. 01/01/2000. We advise the users of all PC controlled systems (like SAFECOM®) to check their PC for Year 2000 compliance. There are software utilities available that can automatically test this. Please contact your PC manufacturer (e.g., Compaq®, Dell, IBM, etc.) for further information.

Footnote C - Setting the Time and Day/Date on the D8112 Alarm Control Panels:

Time:
Press "Command 45". Enter the new time using 24-hour (Military) data entry. E.g. 1:30 = 13:30. Allowable entry range is from 00:01 to23:59. 24:00 is not an allowable entry.
Day / Date:
The panel will have been setup by the alarm installing company to display either "Day of the week" or "Month / Day". Press "Command 46". The current Day or MM/DD will display. Day displays will show (e.g. Friday 6). Days are to be entered using the number value for each day of the week. Sunday = 1, Monday = 2 etc. Enter the desired day number value and press the "Command" key to set. Display will now return to its normal operating mode. Month / Date displays will show (e.g. APR 23). Enter the full Month / Date desired using the number value for the desired month, e.g. 0429) and press the "Command" key to set. Display will now return to its normal operating mode.


Footnote D - CNC events (not door controller events) generated after 23:59 on December 31, 1999 are incorrectly logged on the Readykey Windows software as occurring in 1980. It is important to note the following:

  • This issue does not affect the functionality or reliability of this product;
  • Only internally generated events by the CNC are affected (e.g., communications session and error messages);
  • This issue does not affect events that are routed through the CNC to / from the attached door controller;
  • This will only be evident in Readykey for Windows systems; the DOS product platform decodes the dates differently and does not exhibit this issue;
  • This issue is not present in the newer models of the CNC (known as MKII with six 9-pin data connectors on the back and sold after May 1999).

This issue can be resolved simply by upgrading the EPROM inside the CNC. Contact Radionics Order Processing for a free upgrade kit, K6099-MS.

Motion and Fire Sensors - These products do not contain date function of any kind and are not affected. Some products, including those with motion monitor, have internal time counters for diagnostics based on elapsed time. This information is not viewable. No time data is output or communicated external to the product.


Alpha II is a keypad trade name. Keypads are not listed and have no date and time parameters.

Omegalarm is a panel trade name. Panels need to be identified in the product matrix by model number.


Disclaimers:
1. The products listed have been tested against the Company's documented Product Test Strategy.

2. Information contained herein is subject to change without notice. Detection Systems reserves the right to make changes in design, components, or this information as progress in engineering or information availability may warrant. Any changes will be promptly posted on our web sites (Detectionsys.com and RadionicsInc.com)

3. This and other documents related to the Company's Year 2000 Readiness Disclosure do not create or imply any additional warranty by the Company beyond what was issued at the time the product was purchased.


 

 


AREA FOR
ALARM COMPANIES
AND SECURITY
EMPLOYEES

=CENTRAL  STATIONS  PROTOCOLS 
=SOFTWARE 
=INSTALLATION TIPS and NOTES 
=FORMS 

=PRODUCTS OVERVIEW 
=TECH SUPPORT PHONE NUMBERS 


WEB HOSTING

=DATA CENTER and
CONNECTIVITY

=VIRTUAL PACKAGES DETAILS
=VIRTUAL PACKAGES PRICES
=WEB CONTROL PANEL

=POLICIES


LINKS TO
RELATED SITES


JOKES


DAILY NEWS


CANADA MAP


GLOSSARY


SEARCHING 
WWW 


UNIVERSAL  CURRENCY  CONVERTER


CONTACT US

 


 

  
© Copyright 1997-
2008
Information in this document is subject to change without notice.
Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
UPDATE 05-Jan-2008
MMC&S Inc.


MESSAGE BOARD   ***   ALARM COMPANIES  ***   FREE  USER MANUALS

ALARM EQUIPMENT >>>  dsc * ademco paradox  *  fbi  *  gas/co - detectors  * wireless devices  * fire alarm
 motion detectors *   dual detectors * glass break detectorsmagnetic contactstransformers * battery * siren
 Environmentalcentral station equipmentmonitors * cameras *  recorders * switcher & quads  

INSTALLATION / SERVICE / MONITORING

POINTS  of  INTEREST >>> metric imperial us conversion * frequently asked question  *  statistics 
 how the sensor works  *  y2k * basic security systems 101 

FALSE ALARMS >>>  false alarms fees British Columbia ( CANADA )  *  California (USA)  *  other USA cities  

LINK to AlarmsBC   ***    LINKS TO RELATED SITES   ***     SEARCHING WWW  

WEB HOSTING   * **   DATA CENTER ***  HOSTING PLANS 

JOKES  ***   DAILY NEWS   ***   GLOSSARY   ***    CANADA MAP

 ALARM TECH  HELP >>>  INSTALLATION TIPS  >>> SENTROL Application notes  * ULC Installation tips 
 ULC Level of protection   *  Default Installer codes  *  ADT alarm panel -  Cross Reference   *  Network Cable Simplified 
etc...  etc....

CENTRAL STATIONS PROTOCOLS   *     TECH SUPPORT PHONE NUMBERS   *   SOFTWARE


CONTACT US